Power reduction devices for street lighting

ENERGY SAVINGS AND POWER REDUCTION DEVICES FOR STREET LIGHTING

 

 

WCoffPRD -power reduction device with control wire (reduce then phase is OFF)

WConPRD- power reduction device with control wire (reduce then phase is ON)

  • Switch over to reduced power without applying control voltage
  • 5 minutes of full load operation, independent if control voltage applied or not during switch on(lamp preservation)
  • 3 minutes of full load operation after short mains interruptions independent if control voltage applied
  • Switch over to reduced power when control voltage applied, after delay of 5 minutes.
  • 5 minutes of full load operation, independent if control voltage applied or not during switch on (lamp preservation)
  • 3 minutes of full load operation after short mains interruptions independent if control voltage applied
AC5h/6hPRD- power reduction device with automatic reduction for 6 h after 5h working time. No control cable needed.

AC5hPRD- power reduction device with automatic reduction after 5h.
No control cable needed.

  • Program sequence starts after supply voltage is applied
  • Switch over to reduced power operation after permanently programmed time of 5h (no additional line needed)
  • Reduced operation for 6h
  • Full power operation till supply voltage is switched OFF
  • 3 minutes of full load operation after short mains interruptions
  • Program sequence starts after supply voltage is applied
  • Switch over to reduced power operation after permanently programmed time of 5h (no additional line needed)
  • Reduced operation till supply voltage is switched OFF
  • 3 minutes of full load operation after short mains interruptions

  

ACmidPRD- power reduction device with automatic reduction and middle night detection (for 7h).No control wire needed.

  • Microprocessor controlled
  • No additional cables required
  • Reference point is “natural midnight”.
  • Factory settings, reduces power 3h before reference point power increase follows 4h after reference point
  • Factory settings could be changed via mains supply, if needed.

 

 

EXAMPLE: 19 o’clock street lights are turned ON and at 6 o’clock turned OFF. In this case we have total of 11 hours

long operation, middle point in this case is 5.5 hours which makes “natural midnight” at 00:30, so power goes down

to 50% operation at 21:30 (00:30 – 3h), returns to 100% operation at 04:30 (00:30 + 4h).Power switch always takes

average of last 3 operating times to calculate reference point.

 

 

 

 

 

High-pressure Sodium Lamps (HS)

Lamp Wattage, W

50/35

70/50

100/70

150/100

250/150

400/250

Circuit power (full), W

63

84

115

166

274

434

Circuit power (reduced), W

40

59

79

107

171

288

Energy savings, W

23

25

36

59

103

146

Circuit power reduction

37 %

30 %

31 %

36 %

38 %

34 %

Power-reduced operation/year, h

2190

2190

2190

2190

2190

2190

Energy savings per year, kW

50,37

54,75

78,84

129,21

225,57

319,74

Savings in Energy costs per year, EUR

6,04

6,57

9,46

15,50

27,07

38,36

Payback Period, Years

3,3

3

2,1

1,3

0,7

 

0,5

Energy costs are based on the power price of 0,12 Euro/kWh. Output reduction is based on an assumed period of 6 hours

per night, 365 days a year. Lamps must always be ignited with the higher rated wattage of ballast and not switched down

to reduced wattage before 10 minutes of normal operation after the ignition of a lamp.

 